Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Ann R Coll Surg Engl ; 103(6): 390-394, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33974459

RESUMEN

The COVID-19 pandemic is the most serious health crisis of our time. Global public measures have been enacted to try to prevent healthcare systems from being overwhelmed. The trauma and orthopaedic (T&O) community has overcome challenges in order to continue to deliver acute trauma care to patients and plan for challenges ahead. This review explores the lessons learnt, the priorities and the controversies that the T&O community has faced during the crisis. Historically, the experience of major incidents in T&O has focused on mass casualty events. The current pandemic requires a different approach to resource management in order to create a long-term, system-sustaining model of care alongside a move towards resource balancing and facilitation. Significant limitations in theatre access, anaesthetists and bed capacity have necessitated adaptation. Strategic changes to trauma networks and risk mitigation allowed for ongoing surgical treatment of trauma. Outpatient care was reformed with the uptake of technology. The return to elective surgery requires careful planning, restructuring of elective pathways and risk management. Despite the hope that mass vaccination will lift the pressure on bed capacity and on bleak economic forecasts, the orthopaedic community must readjust its focus to meet the challenge of huge backlogs in elective caseloads before looking to the future with a robust strategy of integrated resilient pathways. The pandemic will provide the impetus for research that defines essential interventions and facilitates the implementation of strategies to overcome current barriers and to prepare for future crises.


Asunto(s)
COVID-19/epidemiología , Prioridades en Salud , Procedimientos Ortopédicos , Heridas y Lesiones/cirugía , Procedimientos Quirúrgicos Ambulatorios , Atención a la Salud/organización & administración , Atención a la Salud/estadística & datos numéricos , Prioridades en Salud/organización & administración , Prioridades en Salud/normas , Humanos , Procedimientos Ortopédicos/estadística & datos numéricos , Traumatología/organización & administración , Traumatología/normas
3.
Ann R Coll Surg Engl ; 103(2): 104-109, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33185459

RESUMEN

INTRODUCTION: There has been guidance from the government and orthopaedic community on how best to ensure the safety of our patients and colleagues as we recommence elective surgery in the UK. The primary aim was to determine what proportion of patients feel they should proceed with their elective hip and knee arthroplasty surgery during the COVID-19 climate. The secondary aim was to investigate what variables affected this decision. METHODS: Patient information from a single surgeon's waiting list in a district general hospital were recorded. A standardised telephone discussion was had with all the patients noting the severity of pain and the potential reasons for not wanting to proceed with surgery. RESULTS: A total of 70.6% (96/136) of patients wished to proceed with surgery; 29.4% (40/136) did not wish to proceed. The decision to proceed with surgery was not correlated with sex, American Society of Anesthesiologists grade or COVID-19 risk. Those who wished to proceed with surgery had a mean age of 68.5 years while those who did not had a mean age of 72.4 years (P = 0.03). Within the matched subgroups, patients under the age of 70 years were more willing to proceed with primary hip arthroplasty surgery (87.9%) compared with primary knee arthroplasty surgery (57.1%; P = 0.007); 75% of the patients who did not wish to proceed with surgery expressed concerns about perioperative COVID-19 infection. CONCLUSION: There is a significant proportion of arthroplasty patients on waiting lists who would be willing to accept the increased risks associated with COVID-19 to undergo surgery on an urgent basis. The subgroup of younger patients awaiting hip arthroplasty is more willing than those awaiting knee arthroplasty to proceed with surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Actitud Frente a la Salud , COVID-19 , Infección Hospitalaria , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Prioridad del Paciente , Anciano , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Riesgo , SARS-CoV-2 , Listas de Espera
4.
Orthop Traumatol Surg Res ; 104(2): 165-170, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29223778

RESUMEN

INTRODUCTION: Kinematic (KA) and mechanical (MA) alignment techniques are two different philosophies of implant positioning that use the same TKA implants. This might generate differences in the resulting prosthetic trochleae parameters between the two techniques of alignment. Our study aim was to test the following hypotheses : (1) mechanically or kinematically aligned femoral implant understuffs the native trochlear articular surface and poorly restores the native groove orientation, and (2) the orientation of the prosthetic trochlear groove and trochlear fill are different between MA and KA. METHODS: Three-dimensional models of the femur were made from segmentation of preoperative Magnetic Resonance Imaging scans (MRIs) of ten subjects with isolated medial tibiofemoral osteoarthritis. In-house planning and analysis software kinematically and mechanically aligned a modern cruciate retaining femoral component and determined differences in parameters of the trochlear fit between native and prosthetic trochleae, and between KA and MA prosthetic trochleae. RESULTS: The MA prosthetic trochleae did not fill (understuffed) the entire length of the native medial facet and the proximal 70% of the native groove and lateral facet, and oriented the trochleae groove 8° more valgus than native. The KA prosthetic trochleae understuffed the proximal 70% of the native trochleae, and had a groove 6° more valgus than native. The KA trochleae understuffed the medial facet distally and oriented the groove 2° less valgus and 3° more internally rotated than the MA trochleae. CONCLUSION: MA and KA prosthetic trochleae substantially understuff and create a prosthetic groove more valgus compared to native trochlear anatomy, and they also differed between each other regarding trochleae stuffing and groove alignment. Although randomized trials have not shown differences in patellofemoral complications between KA and MA, a femoral component designed specifically for KA that more closely restores the native trochlear anatomy might improve patient reported satisfaction and function. LEVEL OF EVIDENCE: Level 2 controlled laboratory study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Femenino , Fémur , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/cirugía , Imagen por Resonancia Magnética , Persona de Mediana Edad
5.
Orthop Traumatol Surg Res ; 103(7): 1069-1073, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28870873

RESUMEN

INTRODUCTION: Kinematic alignment (KA) technique is an alternative technique for positioning a TKA, which aims a patient-specific implant positioning in order to reproduce the pre-arthritic knee anatomy. Because reliability in implant positioning is of interest to obtain reproducible good functional results, our study tests the hypothesis that the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically aligned femoral component are similar. METHODS: Preoperative knee magnetic resonance imaging (MRI) and postoperative knee computed tomography (CT) of 13 patients implanted with a KA Persona® TKA (Zimmer, Warsaw, USA) using manual instrumentation (kinematically-aligned TKA procedure pack®, Zimmer Biomet, Warsaw, USA) were segmented to create 3D femoral models. The kinematic alignment position of the femoral component was planned on the 3D model created from the preoperative MRI. Differences in the positions of the planned and surgically implanted kinematically-aligned femoral component were determined with in-house analysis software. RESULTS: The average differences between the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically-aligned femoral component were inferior to 1mm and no statistically significant. In terms of variability, 62% (8/13) of performed implants matched all four positions within 1.5mm, and the maximum difference was 3mm. CONCLUSION: In this small series, intraoperative kinematic positioning of the femoral component with the specific manual instrumentation closely matched the planned position, which suggests that this technique reliably aligned the flexion-extension axis of the femoral component to the cylindrical axis. LEVEL OF EVIDENCE: Level 3.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Fenómenos Biomecánicos , Femenino , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Osteoartritis de la Rodilla/diagnóstico por imagen , Reproducibilidad de los Resultados , Programas Informáticos , Cirugía Asistida por Computador/instrumentación , Tomografía Computarizada por Rayos X
6.
Orthop Traumatol Surg Res ; 103(7): 1057-1067, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28888523

RESUMEN

BACKGROUND: Mechanically aligned (MA) total knee arthroplasty (TKA) is affected by disappointing functional outcomes in spite of the recent improvements in surgical precision and implant designs. This might suggest the existence of intrinsic technical limitations. Our study aims to compare the prosthetic and native trochlear articular surfaces and to estimate the extent of collateral ligament imbalance, which is technically uncorrectable by collateral ligament release when TKA implants are mechanically aligned. STUDY HYPOTHESIS: Conventional MA technique generates a high rate of prosthetic overstuffing of the distal groove, distal lateral trochlear facet and distal lateral femoral condyle (Hypothesis 1), and technically uncorrectable collateral ligament imbalance (hypothesis 2)? Disregarding the distal femoral joint line obliquity (DFJLO) when performing femoral cuts explains distal lateral femoral prosthetic stuffing and uncorrectable imbalance (hypothesis 3)? METHODS: Twenty patients underwent a conventional MA TKA. Pre-operative MRI-based 3D knee models were generated and MA TKA was simulated. Native and prosthetic trochlear articular surfaces were compared using in-house analysis software. Following the automatic determination by the planning software of the size of the extension and flexion gaps, an algorithm was applied to balance the gaps and the frequency and amplitude of technically uncorrectable knee imbalance were estimated. RESULTS: The conventional MA technique generates a significant slight distal lateral femoral prosthetic overstuffing (mean 0.6mm, 0.8mm, 1.25mm for the most distal lateral facet point, groove, and at the most distal point of lateral femoral condyle, respectively) and a high rate of type 1 and 2 uncorrectable knee imbalance (30% and 40%, respectively). The incidence of distal lateral prosthetic overstuffing (trochlea and condyle) and uncorrectable knee imbalance were strongly to very strongly correlated with the DFJLO (r=0.53 to 0.89). CONCLUSION: Conventional MA technique for TKA generates frequent lateral distal femoral prosthetic overstuffing and technically uncorrectable knee imbalance secondary to disregarding the DFJLO when adjusting the femoral component frontal and axial rotations, respectively. LEVEL OF EVIDENCE: level 4.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Osteoartritis de la Rodilla/diagnóstico por imagen , Programas Informáticos , Cirugía Asistida por Computador/instrumentación
7.
Orthop Traumatol Surg Res ; 103(7): 1047-1056, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28864235

RESUMEN

In spite of improvements in implant designs and surgical precision, functional outcomes of mechanically aligned total knee arthroplasty (MA TKA) have plateaued. This suggests probable technical intrinsic limitations that few alternate more anatomical recently promoted surgical techniques are trying to solve. This review aims at (1) classifying the different options to frontally align TKA implants, (2) at comparing their safety and efficacy with the one from MA TKAs, therefore answering the following questions: does alternative techniques to position TKA improve functional outcomes of TKA (question 1)? Is there any pathoanatomy not suitable for kinematic implantation of a TKA (question 2)? A systematic review of the existing literature utilizing PubMed and Google Scholar search engines was performed in February 2017. Only studies published in peer-reviewed journals over the last ten years in either English or French were reviewed. We identified 569 reports, of which 13 met our eligibility criteria. Four alternative techniques to position a TKA are challenging the traditional MA technique: anatomic (AA), adjusted mechanical (aMA), kinematic (KA), and restricted kinematic (rKA) alignment techniques. Regarding osteoarthritic patients with slight to mid constitutional knee frontal deformity, the KA technique enables a faster recovery and generally generates higher functional TKA outcomes than the MA technique. Kinematic alignment for TKA is a new attractive technique for TKA at early to mid-term, but need longer follow-up in order to assess its true value. It is probable that some forms of pathoanatomy might affect longer-term clinical outcomes of KA TKA and make the rKA technique or additional surgical corrections (realignment osteotomy, retinacular ligament reconstruction etc.) relevant for this sub-group of patients. Longer follow-up is needed to define the best indication of each alternative surgical technique for TKA. Level I for question 1 (systematic review of Level I studies), level 4 for question 2.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla
8.
J Bone Joint Surg Br ; 93(5): 629-33, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21511928

RESUMEN

We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p < 0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/diagnóstico por imagen , Prótesis de la Rodilla , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Articulación de la Rodilla/patología , Articulación de la Rodilla/fisiopatología , Persona de Mediana Edad , Variaciones Dependientes del Observador , Orientación , Cuidados Posoperatorios/métodos , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
9.
Knee Surg Sports Traumatol Arthrosc ; 19(9): 1479-87, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21484388

RESUMEN

PURPOSE: Complications after total knee arthroplasty (TKA) often involve the patellofemoral joint, and problems with patellar maltracking or lateral instability have sometimes been addressed by external rotation of the femoral component. This work sought to measure the changes of knee kinematics caused by TKA and then to optimise the restoration of both the patellofemoral and tibiofemoral joint kinematics, by variation of femoral component internal-external rotation. METHODS: The kinematics of the patella and tibia were measured in eight cadaveric knees during active extension motion. This was repeated with the knee intact, with a Genesis II TKA in the standard position (3° of external rotation) and with the femoral component at ±5° rotation from there. RESULTS: Both patellar and tibial motions were significantly different from normal with the standard TKA rotation, with 3° tibial abduction at 90° flexion and reversal of the screw-home from 5° external rotation to 6° internal rotation. The patella was shifted medially 6 mm in flexion and tilted 7° more laterally near extension. Femoral rotation to address one abnormality caused increased abnormality in other degrees of freedom. Internal and then external rotation of 5° caused tibial abduction and then adduction of 5° at 90° flexion. These femoral rotations also caused increased patellar lateral tilt of 4° with femoral external rotation and decreased tilt by 4° with internal rotation. Thus, correction of tibial abduction in flexion, by external rotation of the femoral component, worsened the patellar lateral tilt near extension. CONCLUSIONS: It was concluded that femoral rotation alone could not restore all aspects of both patellar and tibial kinematics to normal with this specific implant. The clinical relevance of this is that it appears to be inadvisable to reposition the femoral component, in an attempt to improve patellar tracking, if that repositioning may then cause abnormal tibiofemoral kinematics. Further, the pattern of patellar tracking, with the type of TKA used in this study, could not be adjusted to normal by femoral component rotation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Inestabilidad de la Articulación/prevención & control , Prótesis de la Rodilla , Articulación Patelofemoral/fisiopatología , Rango del Movimiento Articular/fisiología , Anciano , Análisis de Varianza , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Inestabilidad de la Articulación/etiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Valores de Referencia , Rotación , Tibia/fisiopatología
10.
Knee Surg Sports Traumatol Arthrosc ; 17(10): 1211-6, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19526222

RESUMEN

Overstuffing the patellofemoral compartment during TKR leads to complications such as maltracking and wear, predisposing to early failure. However, there is no data describing how the patellar construct thickness affects the retinacula. This study instrumented cadaveric knees that had a Genesis II (Smith & Nephew, Memphis, TN, USA) TKR in situ. Sutures were passed along the medial patellofemoral ligament (MPFL) and the deep transverse fibre band of the lateral retinaculum, from the ilio-tibial band (ITB) to the patella. These sutures were attached to displacement transducers. Length changes in the retinacula were measured during knee flexion-extension against the actions of 175 N quadriceps and 30 N ITB tensions. This was done with the natural patellar thickness, then repeated with the patella 2 mm thinner, 2 mm thicker and 4 mm thicker (overstuffed). Each thickness change caused a significant overall slackening or stretching of the MPFL (P < 0.0001 by ANOVA), with 2.3 mm mean stretching (P < 0.001 all angles of knee flexion by post-testing) at 4 mm thicker. The ITB-patellar band was not slackened (P = 0.491) or stretched (P = 0.346) significantly by 2 mm thickness changes. 4 mm thickening stretched the lateral retinaculum 1.1 mm (P = 0.0108). Patellar thickness affected the MPFL more than the lateral retinaculum. This difference reflected the mobile attachment of the lateral retinaculum to the ITB, whereas the MPFL was stretched directly between bony attachments. 2 mm overstuffing did not stretch the retinacula sufficiently to cause mechanical effects.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Ligamento Rotuliano/lesiones , Articulación Patelofemoral/cirugía , Rango del Movimiento Articular , Técnicas de Sutura/efectos adversos , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Cadáver , Humanos , Persona de Mediana Edad
11.
J Bone Joint Surg Br ; 90(8): 1032-8, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18669958

RESUMEN

The rotational alignment of the tibia is an unresolved issue in knee replacement. A poor functional outcome may be due to malrotation of the tibial component. Our aim was to find a reliable method for positioning the tibial component in knee replacement. CT scans of 19 knees were reconstructed in three dimensions and orientated vertically. An axial plane was identified 20 mm below the tibial spines. The centre of each tibial condyle was calculated from ten points taken round the condylar cortex. The tibial tubercle centre was also generated as the centre of the circle which best fitted eight points on the outside of the tubercle in an axial plane at the level of its most prominent point. The derived points were identified by three observers with errors of 0.6 mm to 1 mm. The medial and lateral tibial centres were constant features (radius 24 mm (SD 3), and 22 mm (SD 3), respectively). An anatomical axis was created perpendicular to the line joining these two points. The tubercle centre was found to be 20 mm (SD 7) lateral to the centre of the medial tibial condyle. Compared with this axis, an axis perpendicular to the posterior condylar axis was internally rotated by 6 degrees (SD 3). An axis based on the tibial tubercle and the tibial spines was also internally rotated by 5 degrees (sd 10). Alignment of the knee when based on this anatomical axis was more reliable than either the posterior surfaces or any axis involving the tubercle which was the least reliable landmark in the region.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular/fisiología , Tibia/fisiología , Adulto , Anciano , Artroplastia de Reemplazo de Rodilla/normas , Desviación Ósea/prevención & control , Femenino , Humanos , Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Rotación , Tibia/anatomía & histología , Tibia/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Soporte de Peso/fisiología
12.
J Assist Reprod Genet ; 17(1): 60-6, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10754785

RESUMEN

PURPOSE: Our purpose was to investigate the association between percentage chromomycin A3 (CMA3) positivity of spermatozoa with some sperm parameters and in vitro fertilization rate. METHODS: Spermatozoa were collected from 139 men, washed in PBS, fixed in methanol/glacial acetic acid (3:1), and then spread on slides. CMA3 positivity is expressed as the percentage in 200 spermatozoa. RESULTS: Percentage of CMA3 positivity showed not only a negative correlation with fertilization rate but also a significant difference between fertilizing and nonfertilizing patients. Moreover, percentage of CMA3-positive spermatozoa showed a negative correlation with count and percentage motility and a positive correlation with percentage of abnormal morphology. Percentage of CMA3 positivity also had a positive correlation with some abnormalities of head such as amorphous and macrocephaly. Ultrastructural study showed chromatin unpackaging in high CMA3-positive semen samples in comparison with low CMA3-positive semen samples. CONCLUSION: There is a close relationship among fertilization rate, sperm parameters, and CMA3 positivity and CMA3 could be considered as a useful tool for evaluation of male fertility prior to infertility treatment.


Asunto(s)
Cromomicina A3 , Infertilidad Masculina/diagnóstico , Espermatozoides/fisiología , Coloración y Etiquetado/métodos , Cromatina/ultraestructura , Femenino , Fertilización In Vitro , Humanos , Infertilidad Masculina/patología , Masculino , Recuento de Espermatozoides , Motilidad Espermática , Espermatozoides/ultraestructura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...